Medical device assembly

Mactac medical adhesive products offer a wide range of medical adhesives for medical device, medical self adhesive monitoring pads, self adhesive monitoring electrodes,
 

MACtac offers a range of medical adhesive grades designed for the medical device industry where skin contact is possible (aggressive adhesives suitable with polyethylene). They are used to manufacture monitoring, pacing and defibrillation components and all of them are suitable for skin contact. 

 

See Mactac Medical Adhesive Offer



TM 6563Double-sided foam coated on two sides with acrylic based, hypoallergenic pressure sensitive adhesive. TM-6563 was designed for assembling medical devices where skin contact is possible. It exhibits good adhesion to polyethyleneSBMA

semi bleached kraft release liner

0.8 mm63.5µ
TM 9616Double-sided foam tape coated on two sides with acrylic based, hypoallergenic pressure sensitive adhesive.designed for assembling medical devices where skin contact is possible. It exhibits good adhesion to polyethyleneSBMA

densified, semi-bleached kraft release liner

1.6 mm63.5µ
TM 9942 NKcrosslinked polyethylene foam coated on one side with 594 acrylic based, hypoallergenic pressure sensitive adhesive. The adhesive is protected by a 107 gr brown polycoated kraft release liner.SBMA

polycoated white kraft release liner

0.8 mm63.5 µ
TM 9946Single-sided foam tape with acrylic based, hypoallergenic pressure sensitive adhesive. formulated for sustained contact with the human skin. Designed as a general purpose tape used for EKG pads, grounding pads, IV holders.SBMA

polycoated white kraft release liner

1.6 mm63.5µ
TM 9947Cross linked polyethylene foam coated on one side with acrylic based, hypoallergenic pressure sensitive adhesive. The adhesive is protected by a 80 gr white calendered release linerSBA

white calendered release liner.

1 mm50 µ
TM 9710Double-sided film with acrylic based, hypoallergenic pressure sensitive adhesive. designed for assembling medical devices where skin contact is possible. The adhesive is very aggressive and bonds well to polyethyleneSBA

densified, semi bleached kraft release liner.

12.7µ35.6µ
TM 6570Single-sided film coated with acrylic based, hypoallergenic pressure sensitive adhesive. Designed for mounting electro-medical devices to the human skin. Applications : electrocardiograph pads, grounding pads, etc ..SBMA

densified, semi-bleached kraft release liner

90µ63.5µ
TM 9478Single-sided non woven tape coated with acrylic based, hypoallergenic pressure sensitive adhesive. Designed for use as a breathable medical tape : TENS and stress electrodes plus protective pads and coversSBMA

densified, semi-bleached kraft release liner

68.5 gr/m²355-455 µ
TM 8710PET coated on two sides with a latex free, synthetic elastomer adhesive. The adhesive is protected by an 80 gr SCK release linersynthetic elastomer adhesive

80 gr SCK with a silicone release coating on two sides.

 

 

12.7 µ104 µ
TM 9976-60Cross linked 1.6 mm polyethylene foam coated on one side with an acrylic based, hypoallergenic pressure sensitive adhesive. The adhesive is protected by a 80 gr semi-bleached SCK paper release liner.SBMA

80 gr semi-bleached SCK paper release liner

1.6 mm1643 µ
TM 9979Cross linked polyethylene foam coated on one side with 597acrylic based, hypoallergenic pressure sensitive adhesive. The adhesive is protected by a 80 gr white calendered release linerSBMA

80 gr white calendered release liner.

1.5 mm1550 µ